ASTM E84 |
Product |
Description |
Substrate |
Results |
ASTM E84-08 |
Fireshell® F10E |
ASTM E84 Standard test method for surface burning characteristics of building materials |
fiber cement board and select grade red oak flooring |
Flame 5 Smoke 20 |
Class A & 1/2hour noncombustible rated |
AFES- F1E (15mil) over Douglas fir lumber |
ASTM E84 Standard test method for surface burning characteristics of building materials |
Douglas Fir framing lumber |
Class A 30 Min Non-Combustable Rated MEETS URBAN WILDLAND CODES
|
Class 'A' |
Fireshell® over 2lb. Closed Cell Foam |
ASTM E84 Standard test method for surface burning characteristics of building materials |
2lb. Closed Cell Foam |
Flame 15 Smoke 75 |
Class 'A' |
Heat Shedder®(8mils) over Fireshell® Ultra(8mils) on plywood |
ASTM E84 Standard test method for surface burning characteristics of building materials |
½" CDX plywood |
Flame 0 Smoke 0 |
Class 'A' AQMD Paint System |
HS Series Sealer(7mil) 125ft2/Gal & IP Paint System (5mil) 200ft2/Gal |
California Air Quality Management District - VOC Board. AQMD sponsored ASTM E84 Standard test method for surface burning characteristics of building materials |
1/2" Gypsum |
Flame Spread 5 Smoke 5 |
Class 'A' |
AFES-F1E (15mil) |
ASTM E84 Standard test method for surface burning characteristics of building materials |
Cement Board |
Passed 0.0 |
Class 'A' |
IP-10 Firesafe® Paint (7 mil) |
ASTM E84 Standard test method for surface burning characteristics of building materials |
Firesafe Paint applied on cement board |
Passed Flame Spread 0 Smoke 0 |
Class 'A' |
E84 Class A Impregnated Polyethylene Panel |
ASTM E84 Standard test method for surface burning characteristics of building materials |
50% TPR2 Fire Retardant Impregnated Polyethylene Panel |
Passed Flame Spread 5 Smoke 5 |
Class 'A' |
Class A FR polyester |
ASTM E84 Standard test method for surface burning characteristics of building materials |
Cement Board |
Passed Clas A Flame Spread 15 Smoke 45 |
Miscellaneous |
Product |
Description |
Substrate |
Results |
LEED Credit Compliance |
Misc. |
Appropriate LEED's Sections for credit |
N/A |
AQMD Super Compliant |
EPA Method 24 - VOC test |
Fireshell® F-10E |
VOC test for LEED Compliance |
N/A |
< 1g/l |
SFI 54.1 Thermal, Flame barrier, fire extinguishing & vapor fire resistance specification |
TemprotexTM insulative, fire extinguishing, flexible Barrier coating NASCAR | NHRA
|
Multiple scenario specification: fire extinguishing, fire barrier, thermal barrier extreme duty tests for worldwide race applications
|
various composite, carbon fiber and plastic substrates |
First approved fire extinguishing fire barrier approved for worldwide racing |
Vapor Barrier Test |
AFES F1 Series |
To determine the moisture vapor transmission characteristics of a coating film |
Porous Test Charts |
WVT = 0.5 grains/ft2/hour WVP= 0.9perms |
Durability Test |
AFES Series |
To determine the performance properties of elastomeric high build coating |
Fireshell® Coating |
Passed |
FSIS Incidental Contact |
Fireshell® , Structuresavior®, Firesafe®, and Temprotex® |
USDA Food and Safety Inspection Service Acceptance for Meat and Poultry Plants, "Incidental Food Contact" |
N/A |
Compliant with USDA Regulations |