FIRESHELL F1E

Barrier Coating / Ignition Barrier / Exterior Rated

Part Number: F1E

If you are looking for the best fire rated spray on the market, you have come to the right place. FIRESHELL® (F1E) is the only waterproof, 1-part, non-combustible, fire retardant, intumescing coating complying with AC 377 ICC ES for interior and exterior use. Our fire barrier foam expands up to 2000% and provides oxygen starvation when in contact with fire. This barrier coating / ignition barrier comes in both insulating and fire extinguishing versions and is a non-toxic, drain safe, no fuming, water based coating. Protect your buildings and the people in them with fire rated spray from TPR2. Fires are extremely unpredictable, so it is wise to use fire barrier foam as a necessary precaution.


Applications:
  • Exterior exposed Closed cell/open cell spray foam, Foam panels, roof foam
  • Exterior exposed foam coated piping, boat insulation, ships, barrier foam
  • Cabins, barns, foamed attics, lumber, sheathing, siding, roofs
  • Wild land structures, fireproof weather resistant applications, flexible ducts/hoses/pipes

Approvals:
  • Approved Ignition Barrier over Foam
  • E119 - 1hour & 2 hour rated wall assembly
  • 1/2 Hour Non-combustible rated coating
  • E84 Class "A" verified / zero flame, zero smoke
  • ASTM weather ability
  • ASTM E96 approved Vapor Barrier
  • AQMD super compliant
  • Meets code for cold storage, water treatment facilities and Public Storage Structure's foam walls.
  • Meets ICC urban/wild land interface code requirements for non-combustibility over wood and lumber.

Coating Coverage:
  • Up to 130 ft2/gallon coverage


You will need a Username & Password to view our certification materials.
Please CALL: 860.767.8772



ASTM E119 Test Reports

ASTM E119 PART # PRODUCT D.F.T. DESCRIPTION SUBSTRATE RESULTS
ASTM E119 coated closed cell sprayfoam 15 minute wall assembly test F1E FIRESHELL® Ultra 16 mils Fire Resistance Testing According to Modified ASTM E119 Specifications. 4" Thick Polyurethane Insulation Foam 16 Minute Rating
ASTM E119 coated open cell sprayfoam 15 minute wall assembly test F1E FIRESHELL® Ultra 21 mils Fire Resistance Testing According to Modified ASTM E119 Specifications. 11.5" of 0.5lb density Open Cell Sprayfoam Insulation 34 Minute Rating


ASTM E84 Test Reports

ASTM E84 PART # PRODUCT D.F.T. DESCRIPTION SUBSTRATE RESULTS
Class 'A' F1E FIRESHELL®
ULTRA
15 mils Standard test for surface burning characteristics of building materials Douglas Fir framing lumber Class "A" 30 minute non-combustible
E84 F1E FIRESHELL® Ultra 15 mils Standard test for surface burning characteristics of building materials Cement Board Flame:0 , Smoke:0


Miscellaneous Test Reports

MISCELLANEOUS PART # PRODUCT D.F.T. DESCRIPTION SUBSTRATE RESULTS
Vapor Barrier Test F1E FIRESHELL® See Report To determine the moisture vapor transmission characteristics of a coating film Porous Test Charts WVT = 0.5 grains/ft2/hour
WVP= 0.9perms
FSIS Incidental Contact F1E FIRESHELL® NA USDA Food and Safety Inspection Service Acceptance for Meat and Poultry Plants, "Incidental Food Contact" NA Compliant with USDA Regulations
Mold Resistance F1E FIRESHELL® Ultra NA ASTM D-3273-05 Resistance to growth of mold on the surface of interior coatings in an environmental chamber. ASTM D-3274-02 "Evaluating degree of surface disfigurement of paint film by fungal growth or soil and dirt accumulation Gypsum Wallboard No Mold Growth


ICC AC377 approved Ignition Barriers Test Reports

ICC AC377 approved Ignition Barriers PART # PRODUCT D.F.T. DESCRIPTION SUBSTRATE RESULTS
NFPA 286 with Acc. Criteria AC377 appendix A on CLOSED CELL FOAM F1E FIRESHELL® Ultra 10 mils Flame spread and heat release using Full Scale Room Corner over Closed Cell Foam 2# closed cell foam (10" walls, 11 1/2" ceiling) with F1E compared to 1/4" plywood room superior to plywood, room meets AC377
NFPA 286 with Acc. Criteria AC377 appendix A on OPEN CELL FOAM F1E FIRESHELL® Ultra 10 mils Flame spread and heat release using Full Scale Room Corner over Open Cell Foam 1/2" open cell foam (10" walls, 11 1/2" ceiling) with F1E compared to 1/4" plywood room superior to plywood, room meets AC377
NFPA 286 with Acc. Criteria AC377 appendix A on OPEN CELL FOAM CRAWL SPACES F1E FIRESHELL® Ultra 10 mils Flame spread and heat release using Full Scale Room Corner over open cell foam 3/4# open cell foam (10" walls, 11 1/2" ceiling) with F1E compared to 1/4" plywood room superior to plywood, room meets AC377
NFPA 286 with Acc. Criteria AC377 appendix A BASELINE test NA NA NA BASELINE test: Flame spread and heat release using Full Scale Room Corner over Open Cell Foam Foam (7" walls, 11" ceiling) under 1/4" plywood room Plywood room fails at 4:29 min
Supplemental Product Data
Standard Colors for F10E & F1E
Custom Colors
Unacceptable Open Cell Surface Example
Related Articles

ICC-ES Approves New Fire Test Protocol for Spray Applied Polyurethane Foam in AC377

Birmingham, AL. June 3, 2009, the International Code Council Evaluation Service (ICC-ES) approved changes in AC-377, Acceptance Criteria for Spray Allied Polyurethane Foam. This approval had the effect of sun-setting a previous fire testing method and implementing a new one, with phaseout milestones extending to December 2010.

The new fire testing protocol, an NFPA 286 test modified for the purposes of testing alternative ignition barriers for SPF, becomes one of several available tests recognized within the AC-377. Full Article